feat: strengthen VLAN50 canary egress guard and document its lifecycle
Some checks failed
validate / lint (push) Failing after 1s
Some checks failed
validate / lint (push) Failing after 1s
Diagnosed the vlan50-canary FailedCreatePodSandBox->net1-timeout failure as a stale Pod artifact of the Multus DaemonSet rollout race (sandbox created via a transient daemon/shim state mid-rollout; the current, fully-settled daemon's own logs show no ADD for that UID, only a DEL). No defect found in 02-daemonset.yaml or 10-nad-vlan50.yaml; both are unchanged. Independent of that diagnosis, harden the shared guard script per review: print safe interface/address/route diagnostics before every FATAL exit; validate net1 actually carries the workload's expected static /24 address rather than just existing; add arping-based duplicate-address and gateway-reachability checks before installing the net1 default route (exit-code semantics verified against arping's own source). Requires EXPECTED_VLAN50_IP and NET_RAW (for arping's raw ARP sockets) on every consumer - wired into 20-canary.yaml now, qbittorrent.yaml/jdownloader.yaml need the same when they're migrated. Document the canary's Pod lifecycle: restartPolicy: Never means a Failed canary never reruns on its own, and Argo "Synced" only reflects manifest match, not runtime success - recreate it (new UID) after any Multus/CNI change before trusting its result. Recommend keeping it a manually recreated, controller-less Pod rather than a Job/Deployment, since unattended auto-retry risks a duplicate-address race on its static .100 IP - the exact class of bug this diagnosis just walked through. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
This commit is contained in:
parent
f1bdf11f1e
commit
26894d16ce
@ -55,10 +55,16 @@ spec:
|
||||
value: "10.43.0.0/16"
|
||||
- name: NODE_IP
|
||||
value: "10.10.40.20"
|
||||
- name: EXPECTED_VLAN50_IP
|
||||
value: "10.10.50.100"
|
||||
securityContext:
|
||||
capabilities:
|
||||
drop: ["ALL"]
|
||||
add: ["NET_ADMIN"]
|
||||
# NET_RAW alongside NET_ADMIN: the guard script's arping-based
|
||||
# duplicate-address and gateway-reachability checks build raw
|
||||
# ARP frames, which the kernel gates on CAP_NET_RAW specifically
|
||||
# — see vlan50-egress-guard-script.yaml's header comment.
|
||||
add: ["NET_ADMIN", "NET_RAW"]
|
||||
volumeMounts:
|
||||
- name: guard-script
|
||||
mountPath: /scripts
|
||||
|
||||
@ -32,7 +32,76 @@ comment. Nothing here applies to the cluster just because it's merged to
|
||||
and `/var/lib/rancher/k3s/agent/etc/cni/net.d` now has a generated
|
||||
`00-multus.conf`, *then* 10, *then* — only with separate approval — 20.
|
||||
|
||||
## Why macvlan bridge, not ipvlan
|
||||
## Canary lifecycle — re-running it after a Multus/CNI change
|
||||
|
||||
**A canary that already reached `Failed` will never rerun on its own, and
|
||||
an Argo "Synced" status does not mean it passed.** `20-canary.yaml` sets
|
||||
`restartPolicy: Never` and has a fixed name (`vlan50-canary`, no owning
|
||||
Deployment/Job/controller) — deliberately, so nothing ever recreates it
|
||||
automatically (see "Should this become a Deployment/Job instead?" below
|
||||
for why that's load-bearing, not incidental). Two consequences that have
|
||||
each caused real confusion live (2026-08-24), diagnosed from cluster
|
||||
evidence rather than assumed:
|
||||
|
||||
- Once the Pod object reaches `phase: Failed`, it stays exactly as it is
|
||||
forever — Kubernetes does not retry a `restartPolicy: Never` Pod, full
|
||||
stop. Fixing the underlying Multus/CNI DaemonSet does **not** make this
|
||||
Pod try again; it is inert. The only way to get a fresh attempt is to
|
||||
delete and recreate the Pod object itself (new UID, new sandbox, new
|
||||
CNI ADD from scratch).
|
||||
- Argo reporting `multus` as `Synced` only means the *live Pod manifest
|
||||
matches what's in Git* — for a bare Pod (not a Deployment), that
|
||||
comparison is satisfied by the existing (possibly long-Failed) Pod
|
||||
object as-is. Argo has no reason to touch it, so "Synced" here proves
|
||||
nothing about whether the canary actually ran successfully, or even
|
||||
about when it last ran. Don't read Synced as "passing."
|
||||
|
||||
A real example of what this produces if missed: after a DaemonSet fix
|
||||
lands and rolls out, the *node* briefly passes through an inconsistent
|
||||
state (old Multus daemon torn down, new one's init containers still
|
||||
installing plugins, new daemon not started yet — a few seconds to low
|
||||
tens of seconds depending on image pull/init time). A `FailedCreatePodSandBox`
|
||||
retry loop that happens to land its next attempt inside that exact
|
||||
window can produce a Pod that *looks* alive (sandbox created, init
|
||||
container starts, primary `eth0` interface up) but whose secondary
|
||||
`net1` attach never actually completed — no `AddedInterface` event for
|
||||
it, no `k8s.v1.cni.cncf.io/network-status` annotation, the guard script's
|
||||
own `net1` wait times out. That Pod is now permanently `Failed` and
|
||||
permanently stale evidence about the *current* DaemonSet state — its logs
|
||||
and events describe a multus-daemon instance that may no longer exist.
|
||||
Treating that as proof of a live code defect (rather than recreating the
|
||||
Pod first) risks chasing a bug that was already fixed.
|
||||
|
||||
**After any change to `02-daemonset.yaml`, `10-nad-vlan50.yaml`, or the
|
||||
node's CNI binaries**, the only trustworthy re-test is:
|
||||
|
||||
1. Wait for the DaemonSet rollout to actually finish and be Ready —
|
||||
`kubectl -n kube-system rollout status daemonset/kube-multus-ds`.
|
||||
2. Delete the old (Failed) canary Pod — `kubectl -n downloads delete pod
|
||||
vlan50-canary` (or via the Argo UI).
|
||||
3. Recreate it fresh — `kubectl apply -f manifests/multus/20-canary.yaml`
|
||||
(or a selective Argo sync of just that resource).
|
||||
4. Record the **new** Pod UID (`kubectl -n downloads get pod vlan50-canary
|
||||
-o jsonpath='{.metadata.uid}'`) and evaluate only logs/events tied to
|
||||
that UID going forward — old aggregated events for the previous UID
|
||||
are not evidence about this attempt.
|
||||
|
||||
### Should this become a Deployment/Job instead, so it retries itself?
|
||||
|
||||
Deliberately not, at least not while `ipam.type: static` has no
|
||||
allocator behind it (see above) and this canary is hardcoded to
|
||||
`10.10.50.100`. A controller that recreates the Pod automatically (a
|
||||
`Job`, a `Deployment` with `replicas: 1`) would retry through exactly the
|
||||
kind of transient window described above *without* a human confirming
|
||||
the previous attempt's netns was actually torn down cleanly first — two
|
||||
overlapping attempts (a slow-terminating old Pod and a freshly-started
|
||||
new one) both claiming `.100` on the same L2 segment is precisely the
|
||||
duplicate-address scenario the guard script's `arping -D` check now
|
||||
exists to catch, not something to engineer back in via unattended
|
||||
retries. Keeping this a manually recreated, controller-less Pod means
|
||||
recreation only ever happens when someone is actually watching the
|
||||
outcome — that property is worth more here than convenience. If this
|
||||
changes (e.g. a real per-IP allocator is introduced later), revisit.
|
||||
|
||||
The managed switch accepts multiple source MAC addresses on nik-debian's
|
||||
port (confirmed in the session that authored this plan — see the
|
||||
|
||||
@ -21,12 +21,26 @@
|
||||
# Required env on the init container: VLAN50_GATEWAY, TECHNITIUM_IP,
|
||||
# POD_CIDR, SERVICE_CIDR, NODE_IP (nik-debian's own node IP —
|
||||
# kubelet-originated probe traffic to the pod arrives via the primary
|
||||
# eth0 gateway and its replies must go back the same way, not out net1).
|
||||
# eth0 gateway and its replies must go back the same way, not out net1),
|
||||
# EXPECTED_VLAN50_IP (this workload's static VLAN 50 address, without a
|
||||
# prefix — .100 for the canary, .10/.11/.12 for qBittorrent/JDownloader/
|
||||
# the future browser-vpn-proxy — must match the /24 the NAD's static
|
||||
# IPAM assigned via the pod's own k8s.v1.cni.cncf.io/networks annotation,
|
||||
# checked below rather than trusted blindly).
|
||||
# Optional: EXTRA_ETH0_CIDR (space-separated, for any additional
|
||||
# narrowly-required cluster path — leave unset unless a specific need is
|
||||
# identified and reviewed; do not widen this to a blanket 10.0.0.0/8 or
|
||||
# similar).
|
||||
#
|
||||
# The init container needs NET_RAW in addition to NET_ADMIN (both, drop
|
||||
# ALL otherwise) — arping (used below for the duplicate-address and
|
||||
# gateway-reachability checks) builds raw ARP frames over an AF_PACKET
|
||||
# socket, which the kernel gates on CAP_NET_RAW specifically; NET_ADMIN
|
||||
# alone is not sufficient and arping fails immediately without it. This
|
||||
# is a hard runtime dependency of this script now, not optional
|
||||
# hardening — a pod wiring this ConfigMap in without also granting
|
||||
# NET_RAW will fail closed at the arping step every time.
|
||||
#
|
||||
# Corrected from an earlier version after code review: that version
|
||||
# deleted the eth0 default route and then routed pod/service CIDR
|
||||
# directly `dev eth0` with no gateway — remote pod addresses (on other
|
||||
@ -55,6 +69,18 @@ data:
|
||||
: "${POD_CIDR:?required}"
|
||||
: "${SERVICE_CIDR:?required}"
|
||||
: "${NODE_IP:?required}"
|
||||
: "${EXPECTED_VLAN50_IP:?required}"
|
||||
|
||||
# Safe to print in full: interface/address/route state only, never
|
||||
# touches the PIA token, WireGuard keys, or any other credential —
|
||||
# those live entirely on minisforum's side of the tunnel, not in this
|
||||
# pod's netns at all.
|
||||
print_diagnostics() {
|
||||
echo "[vlan50-egress-guard] diagnostics follow:" >&2
|
||||
ip -details link show >&2 || true
|
||||
ip -4 address show >&2 || true
|
||||
ip -4 route show table all >&2 || true
|
||||
}
|
||||
|
||||
echo "[vlan50-egress-guard] waiting for net1"
|
||||
ready=0
|
||||
@ -67,13 +93,65 @@ data:
|
||||
done
|
||||
if [ "${ready}" -ne 1 ]; then
|
||||
echo "[vlan50-egress-guard] FATAL: net1 did not appear after 30s — refusing to start without the VLAN 50 attachment (Multus/NAD required, no eth0-only fallback)" >&2
|
||||
print_diagnostics
|
||||
exit 1
|
||||
fi
|
||||
|
||||
echo "[vlan50-egress-guard] validating net1's address: expecting ${EXPECTED_VLAN50_IP}/24"
|
||||
addr_ok=0
|
||||
for _ in $(seq 1 15); do
|
||||
if ip -4 -o address show dev net1 | awk '{print $4}' | grep -qx "${EXPECTED_VLAN50_IP}/24"; then
|
||||
addr_ok=1
|
||||
break
|
||||
fi
|
||||
sleep 1
|
||||
done
|
||||
if [ "${addr_ok}" -ne 1 ]; then
|
||||
echo "[vlan50-egress-guard] FATAL: net1 does not carry the expected ${EXPECTED_VLAN50_IP}/24 after 15s (interface existing is not enough — the static IPAM result itself has to match what this workload is supposed to have). Actual net1 address(es):" >&2
|
||||
ip -4 -o address show dev net1 >&2 || true
|
||||
print_diagnostics
|
||||
exit 1
|
||||
fi
|
||||
echo "[vlan50-egress-guard] net1 has ${EXPECTED_VLAN50_IP}/24"
|
||||
|
||||
# "Duplicate or tentative" for IPv4: the kernel's IFA_F_TENTATIVE flag
|
||||
# (what `ip addr show` reports as "tentative") is an IPv6 DAD concept
|
||||
# only — the static IPAM CNI plugin used here does no IPv4 DAD of its
|
||||
# own, so there is no tentative *state* to check for IPv4. What
|
||||
# actually matters — whether some OTHER host on VLAN 50 already holds
|
||||
# this address — is checked directly with an ARP probe instead.
|
||||
echo "[vlan50-egress-guard] checking ${EXPECTED_VLAN50_IP} is not already in use on VLAN 50 (ARP duplicate check)"
|
||||
if ! arping -D -c 2 -w 2 -I net1 "${EXPECTED_VLAN50_IP}" >/tmp/arping-dup.log 2>&1; then
|
||||
echo "[vlan50-egress-guard] FATAL: ${EXPECTED_VLAN50_IP} appears to already be in use on VLAN 50 — arping -D got a reply from another host, meaning this address is a duplicate. Refusing to proceed with a conflicting static IP. arping output:" >&2
|
||||
cat /tmp/arping-dup.log >&2 || true
|
||||
print_diagnostics
|
||||
exit 1
|
||||
fi
|
||||
echo "[vlan50-egress-guard] no duplicate detected for ${EXPECTED_VLAN50_IP}"
|
||||
|
||||
# L2 (ARP) reachability, checked before this gateway is trusted with
|
||||
# the default route below — deliberately not an ICMP ping instead:
|
||||
# ARP resolution is a hard prerequisite for delivering any IP packet
|
||||
# over Ethernet at all, so it is a reliable, low-false-positive proof
|
||||
# the gateway is actually there; an ICMP probe would additionally
|
||||
# depend on the gateway choosing to answer echo requests, which many
|
||||
# routers disable for unrelated security reasons while still routing
|
||||
# traffic completely normally — that would risk failing this check
|
||||
# closed for a gateway that works fine.
|
||||
echo "[vlan50-egress-guard] checking VLAN 50 gateway ${VLAN50_GATEWAY} answers ARP on net1 before trusting it"
|
||||
if ! arping -c 3 -w 3 -I net1 "${VLAN50_GATEWAY}" >/tmp/arping-gw.log 2>&1; then
|
||||
echo "[vlan50-egress-guard] FATAL: VLAN 50 gateway ${VLAN50_GATEWAY} did not answer ARP on net1 — refusing to install it as the default route. arping output:" >&2
|
||||
cat /tmp/arping-gw.log >&2 || true
|
||||
print_diagnostics
|
||||
exit 1
|
||||
fi
|
||||
echo "[vlan50-egress-guard] gateway ${VLAN50_GATEWAY} is reachable"
|
||||
|
||||
echo "[vlan50-egress-guard] capturing the original eth0 default gateway"
|
||||
ETH0_GATEWAY=$(ip route show default dev eth0 2>/dev/null | awk '/^default/ {print $3; exit}')
|
||||
if [ -z "${ETH0_GATEWAY}" ]; then
|
||||
echo "[vlan50-egress-guard] FATAL: could not identify eth0's original default gateway — refusing to proceed. Pod/service CIDR routes below need it explicitly (those destinations are not on-link on eth0), and continuing without it would either leave them unreachable or silently do nothing." >&2
|
||||
print_diagnostics
|
||||
exit 1
|
||||
fi
|
||||
echo "[vlan50-egress-guard] eth0 gateway: ${ETH0_GATEWAY}"
|
||||
|
||||