| switchbot-control | Gated SwitchBot Cloud device control via the local reference CLI (tmp/reference/switchbot-control-reference) — turn-on/off, fan/AC/lock commands, and custom IR buttons. Always resolves and inspects the target first, always dry-runs before a real send, always requires explicit user approval before executing. |
SwitchBot Control (gated)
This wraps tmp/reference/switchbot-control-reference/scripts/switchbotctl,
the full control CLI. Every real control call fires a real signal at real
hardware (an actual IR blast, an actual lock toggle) — treat every non-dry-run
invocation as something you are asking permission to do, not something you
just do.
Required sequence, every time
- Resolve the device. Use the
switchbot-readskill (list all/list remotes/list switches/list locks) to find the exactdeviceIdfor the device the user named. Never guess an ID or reuse one from memory without re-confirming it still matches — if more than one device could match the name, ask which one; never pick one silently. - Inspect the interface. Run
switchbot-read interface DEVICE_IDand confirm the command you're about to send is actually in its documentedcommandslist (or, for a custom button, that the device is an infrared remote wherecustomize-type commands apply). - Dry-run first. Always construct and check the exact call with
--dry-runbefore ever running it for real:
Confirm the echoedcd tmp/reference/switchbot-control-reference GOWORK=off ./scripts/switchbotctl ac DEVICE_ID 24 cool medium on --dry-runcommand/parameter/commandTypein the dry-run output is exactly what you intend. - Ask for explicit approval before running the same command without
--dry-run. State the exact device (name + ID) and the exact action in plain language. Do not treat a general "go ahead with the plan" from earlier in the conversation as approval for a specific real control call — ask again, per command, right before running it. - Execute once. Run the approved command exactly once. Do not retry automatically on failure or on an ambiguous result — a repeated lock, toggle, Bot press, or custom IR command can produce a real second action (e.g. re-toggling something back off). If it needs retrying, ask first.
- Treat success as API acceptance, not physical confirmation. SwitchBot
Cloud's infrared control is fire-and-forget — a
200/statusCode: 100response means the cloud accepted the command, not that the appliance actually received or acted on the IR signal.
Custom IR buttons (button) need the user, not a guess
GOWORK=off ./scripts/switchbotctl button DEVICE_ID "Exact Button Name" --dry-run
SwitchBot's API cannot enumerate a device's learned custom button names — they only exist as case-sensitive labels in the SwitchBot app. Never approximate, guess, or case-fold a button name. If you don't have the exact label from the user, stop and ask for it rather than trying a plausible guess.
Command reference (see tmp/reference/switchbot-control-reference/README.md for the full list)
switchbotctl turn-on DEVICE_ID [--dry-run]
switchbotctl turn-off DEVICE_ID [--dry-run]
switchbotctl press DEVICE_ID [--dry-run]
switchbotctl lock DEVICE_ID [--dry-run]
switchbotctl unlock DEVICE_ID [--dry-run]
switchbotctl fan DEVICE_ID swing|timer|lowSpeed|middleSpeed|highSpeed [--dry-run]
switchbotctl ac DEVICE_ID TEMPERATURE MODE FAN_SPEED POWER [--dry-run]
switchbotctl button DEVICE_ID "Exact Button Name" [--dry-run]
switchbotctl send DEVICE_ID COMMAND PARAMETER COMMAND_TYPE [--dry-run] # generic escape hatch
Always run from tmp/reference/switchbot-control-reference/ with
GOWORK=off prefixed (this repo's root go.work doesn't include this nested
module — see the switchbot-read skill for why not to fix that by editing
go.work).
Hard rules
- Never read, print, edit, source, or expose
.envin this directory. - Never add an automatic hook, cron, or script that calls
switchbotctlwithout a human in the loop for that specific invocation. - This CLI is a development/testing aid only — it is not a dependency of
ha-gateway. The actualRemoteServiceimplementation inha-gatewayhas its own hand-rolled SwitchBot HTTP client (seeplan.md); use this CLI to discover device IDs and verify command behavior during development, not as something the running services call at runtime.